Certification
One row per market, one label per certificate or approval. Only labels marked Issued are documents in the name of SafeWav. The other labels show where the work stands.
ALL
All markets
Company and agent
Issued
ISO 9001:2015
Quality management system
CCS · No. 00525Q4154R0S · Valid to 2028-09-07
In progress
PFAS test report
FW-18 agent. Tested 2024-11; final report copy pending
TÜV Rheinland
CN
China
Home market
Issued
Fire product technical appraisal certificate
Water-based extinguishing agent for lithium-ion batteries, FW-1840
CCCF · No. JD2025020340 · Valid to 2029-01-27
Issued
Type test report
FW-1840 agent, 2025-10
Tianjin Fire Research Institute · No. Gn202501562-01
KR
Korea
With our exclusive distributor
In progress
KFI type approval
3 L and 6 L extinguishers
KFI
Planned
K-REACH registration
FW-18 agent
Planned
Korean MSDS (KOSHA)
FW-18 agent
JP
Japan
Second market
In progress
Market access route
Route under evaluation. No certificate yet
EU
European Union
3 L · 6 L · 6 L LT
Planned
EN 3-7
Portable extinguishers, three models. Fire tests planned for 2027-02
Kiwa
Planned
EN 3-11
Lithium-ion battery fire rating, 3 L and 6 L. Tests planned for 2027-02
Planned
NTA 8133
Netherlands, lithium-ion battery fires
Supplier certificate
PED 2014/68/EU, Module H
Held by our cylinder manufacturer for cylinders and assemblies. Not an approval of the SafeWav extinguisher
TÜV SÜD · Valid to 2029-10-25
LATAM
Latin America
Paraguay · Uruguay · Brazil
Planned
National approvals
Scheme to be chosen per country
Status as of 2026-11-27. In progress and Planned are not certifications. Distributors can request copies of issued documents.
Test plan · EU
The three EU models go to an independent laboratory for the EN 3 tests. The plan below shows what is tested and when. Ratings are targets until the test reports are issued.
Models and tests
| Model | Tests | Target rating |
|---|---|---|
| MS/AL33 L | EN 3-7 · EN 3-11 | 8A |
| MS/AL66 L | EN 3-7 · EN 3-11 | 13A |
| MS/AL6-LT6 L · −20 °C | EN 3-7 | 13A |
Test laboratory: Kiwa GmbH, Freiberg, Germany
Steps
Technical files and quotations2026-11In progress
Drawings, parts lists, data sheets and label artwork prepared for the laboratory. Quotations for the EN 3-7 tests of all three models received.
Fire tests2027-02Planned
Fire test session at the laboratory, including the lithium-ion battery fire tests for the 3 L and 6 L models.
Function and laboratory testsDate not fixedPlanned
The remaining EN 3-7 tests on filled extinguishers: discharge, operating temperature, corrosion, mechanical strength.
Test reports and labelDate not fixedPlanned
One report per model. The confirmed ratings then go on the label and into the product tables.
A test plan is not a certification. Target ratings are the values we declare to the laboratory; they are confirmed, or changed, by the test reports. Dates can move with the laboratory schedule.
Distributors receive copies of issued certificates and reports. One form starts the process.