  "meta": {
    "title": "FW-18 Base Data Sheet",
    "version": "1.0",
    "date": "2026-11-26",
    "brand": "SafeWav",
    "product": "FW-18",
    "product_description": "Water-based, fluorine-free fire extinguishing agent developed for lithium-ion battery fires",
    "source": {
      "document": "R&D and Application of FW-18 Dedicated Fire Extinguishing Agent for Lithium-ion Batteries",
      "document_date": "2026-01-27",
      "slides": 26
    },
    "rule": "Every FW-18 figure shown on the website is read from this file. To change a figure, change it here.",
    "basis": {
      "stated": "Stated in the source document as text or in a table.",
      "chart": "Read from a chart image in the source document (digitized; approximate).",
      "method": "Test set-up, procedure or acceptance criterion described in the source document.",
      "derived": "Calculated from other entries in this sheet."
    }
  },
  "facts": {
    "cooling_capacity": {
      "label": "Cooling capacity",
      "value": 330,
      "unit": "%",
      "display": "330%",
      "reference": {
        "label": "Deionized water",
        "value": 100,
        "display": "100%"
      },
      "detail": "Cumulative heat exposure reduction relative to deionized water (= 100%).",
      "slide": 10,
      "basis": "stated"
    },
    "pfas": {
      "label": "PFAS & PFOS content",
      "value": 0,
      "unit": "",
      "display": "0% PFAS",
      "reference": {
        "label": "Deionized water",
        "value": 0,
        "display": "None"
      },
      "detail": "Fluorine-free. PFAS test report by TÜV Rheinland (report no. 178209196b 001, testing period 2024-11-18 to 2024-11-22).",
      "slide": 10,
      "basis": "stated"
    },
    "electrical_conductivity": {
      "label": "Electrical conductivity",
      "value": 6.7,
      "unit": "μS/cm",
      "display": "6.7 μS/cm",
      "reference": {
        "label": "Deionized water",
        "value": 2.28,
        "display": "2.28 μS/cm"
      },
      "slide": 10,
      "basis": "stated"
    },
    "dielectric_withstand": {
      "label": "Voltage withstand",
      "value": 1500,
      "unit": "V",
      "display": "No breakdown at 1500 V",
      "detail": "1500 V withstand test: no breakdown. Test report dated 2025-08-14.",
      "slide": 10,
      "basis": "stated"
    },
    "freezing_point": {
      "label": "Freezing point",
      "value": -40,
      "unit": "°C",
      "display": "−40 °C",
      "reference": {
        "label": "Deionized water",
        "value": 0,
        "display": "0 °C"
      },
      "detail": "The measured cooling curve shows the freezing plateau at about −41 °C.",
      "slide": 10,
      "basis": "stated"
    },
    "explosion_overpressure": {
      "label": "Explosion overpressure vs. air explosion",
      "value": -30.8,
      "unit": "%",
      "display": "−30.8%",
      "reference": {
        "label": "Deionized water",
        "value": 11.8,
        "display": "+11.8%"
      },
      "detail": "Change in peak explosion overpressure compared with the explosion in air.",
      "slide": 10,
      "basis": "stated"
    },
    "operating_temperature": {
      "label": "Ambient temperature range",
      "value": [
        -40,
        60
      ],
      "unit": "°C",
      "display": "−40 °C to 60 °C",
      "slide": 21,
      "basis": "stated"
    },
    "lfp_max_temp_after_extinguishing": {
      "label": "Maximum temperature after extinguishing (LFP pack, fixed system)",
      "value": 100,
      "unit": "°C",
      "display": "< 100 °C",
      "comparison": [
        {
          "label": "Deionized water",
          "display": "> 400 °C"
        },
        {
          "label": "A mainstream Li-ion extinguishing agent",
          "display": "> 500 °C"
        }
      ],
      "slide": 14,
      "basis": "stated"
    },
    "lfp_flame_out": {
      "label": "Flame extinguished (LFP pack, fixed system)",
      "value": 2,
      "unit": "s",
      "display": "2 s, no re-ignition",
      "comparison": [
        {
          "label": "Deionized water",
          "display": "2 min, re-ignition"
        },
        {
          "label": "A mainstream Li-ion extinguishing agent",
          "display": "1 min 20 s, re-ignition"
        }
      ],
      "slide": 12,
      "basis": "stated"
    },
    "reignition": {
      "label": "Re-ignition in the battery fire tests",
      "value": 0,
      "unit": "",
      "display": "Zero Re-ignition",
      "detail": "No re-ignition in the LFP fixed-system test, the LCO test (20 min observation) and the NCM test with FW-18.",
      "slide": 12,
      "basis": "stated"
    },
    "lco_pack_energy": {
      "label": "LCO pack extinguished with one 6 L extinguisher",
      "value": 710.4,
      "unit": "Wh",
      "display": "710.4 Wh",
      "slide": 16,
      "basis": "stated"
    },
    "ncm_pack_energy": {
      "label": "NCM pack extinguished with one 6 L extinguisher",
      "value": 1128.5,
      "unit": "Wh",
      "display": "1128.5 Wh",
      "slide": 18,
      "basis": "stated"
    },
    "particle_size": {
      "label": "Dispersed-phase particle size",
      "value": [
        1,
        100
      ],
      "unit": "nm",
      "display": "1–100 nm",
      "slide": 9,
      "basis": "stated"
    }
  },
  "property_table": {
    "title": "Key technical specifications compared with deionized water",
    "slide": 10,
    "rows": [
      "cooling_capacity",
      "electrical_conductivity",
      "pfas",
      "freezing_point",
      "explosion_overpressure",
      "dielectric_withstand"
    ]
  },
  "technology": {
    "slide": 9,
    "type": "Microemulsion: a thermodynamically stable system formed by the micellar reaction of an oil phase, a water phase, a surfactant and a co-surfactant.",
    "points": [
      "Dispersed oil phase of 1–100 nm, uniform in size and spherical.",
      "Low electrical conductivity.",
      "Can decompose and absorb combustible gases such as H₂ and CO.",
      "Chemical inhibition interrupts the combustion chain reaction; physical cooling removes heat from the cell surface."
    ],
    "core_functions": [
      "Rapid fire suppression",
      "High-efficiency cooling",
      "Effective explosion suppression",
      "Termination of thermal runaway",
      "Insulating and non-conductive"
    ]
  },
  "scope": {
    "slide": 21,
    "cell_chemistries": [
      "LCO (lithium cobalt oxide)",
      "NCM (lithium nickel cobalt manganese oxide)",
      "LFP (lithium iron phosphate)"
    ],
    "equipment": [
      "Portable extinguishers",
      "Fixed fire protection systems"
    ],
    "fire_classes": [
      "Lithium-ion battery fires",
      "Class A"
    ]
  },
  "tests": [
    {
      "id": "lfp-fixed-system",
      "title": "Fixed fire extinguishing system test: LFP pack",
      "slides": [
        11,
        12,
        13,
        14
      ],
      "kind": "In-house comparison test, three agents under the same procedure",
      "method_reference": "General technical requirements for fire prevention and control devices for lithium-ion power battery boxes of electric buses",
      "method_reference_slide": 11,
      "setup": [
        {
          "label": "Cells",
          "value": "CATL lithium iron phosphate (LiFePO₄ / graphite), 173 × 46 × 133 mm"
        },
        {
          "label": "Test pack",
          "value": "3P4S: three cells in parallel per module, four modules in series"
        },
        {
          "label": "Preconditioning",
          "value": "Fully charged 48 h before the test; 3.6–3.65 V per cell verified"
        },
        {
          "label": "Instrumentation",
          "value": "12 thermocouple channels (CH01–CH12)"
        },
        {
          "label": "Suppression",
          "value": "Water-mist system, constant 4 MPa, 240 s spray"
        }
      ],
      "procedure": [
        "Keep the fully charged battery in an overcharged state.",
        "After 180 s, heat the battery with a heating plate for 780 s, then stop heating and overcharging and let thermal runaway develop.",
        "Activate the water-mist system: constant 4 MPa for 240 s.",
        "Observe the pack after extinguishing."
      ],
      "criteria": [
        "The flame is completely extinguished and there is no re-ignition within 1 hour.",
        "After 1 hour, at least one unburned battery cell remains."
      ],
      "agents": [
        {
          "id": "deionized-water",
          "label": "Deionized water",
          "flame_out": "2 min",
          "reignition": true,
          "max_after_extinguishing": "> 400 °C",
          "video": "lfp-fixed-deionized-water",
          "photo": "lfp-fixed-result-deionized-water"
        },
        {
          "id": "mainstream-agent",
          "label": "A mainstream Li-ion extinguishing agent",
          "flame_out": "1 min 20 s",
          "reignition": true,
          "max_after_extinguishing": "> 500 °C",
          "video": "lfp-fixed-mainstream-agent",
          "photo": "lfp-fixed-result-mainstream-agent"
        },
        {
          "id": "fw18",
          "label": "FW-18",
          "flame_out": "2 s",
          "reignition": false,
          "max_after_extinguishing": "< 100 °C",
          "video": "lfp-fixed-fw18",
          "photo": "lfp-fixed-result-fw18"
        }
      ],
      "phases": [
        {
          "id": "heating",
          "ids": [
            "overcharge",
            "heating"
          ],
          "label": "Heating / Overcharging",
          "detail": "Fully charged pack held in overcharge (180 s), heating plate on (780 s)"
        },
        {
          "id": "runaway",
          "label": "Runaway",
          "detail": "Heating and overcharge off; runaway develops"
        },
        {
          "id": "spray",
          "label": "Spray",
          "detail": "Water-mist system, 4 MPa, 240 s"
        },
        {
          "id": "observation",
          "label": "After Extinguishing",
          "detail": "Pack left under observation"
        }
      ],
      "conclusions": [
        "Cooling effect: FW-18 > a mainstream Li-ion extinguishing agent > deionized water.",
        "FW-18 terminated thermal runaway; with the other two agents the pack re-ignited."
      ],
      "curves": "lfp_fixed_system",
      "images": [
        "lfp-fixed-test-setup"
      ]
    },
    {
      "id": "lco-handheld",
      "title": "Portable extinguisher test: LCO pack",
      "slides": [
        15,
        16
      ],
      "kind": "In-house test",
      "method_reference": "KFI certification criteria for the extinguishing performance of extinguishers on small lithium-ion battery fires, No. 630, 2024-12-18",
      "method_reference_slide": 15,
      "setup": [
        {
          "label": "Cells",
          "value": "New LiPo pouch cells, LCO (LiCoO₂), 8000 mAh, 3.7 V"
        },
        {
          "label": "Test pack",
          "value": "6 groups of 4 cells in series (14.8 V per group), 710.4 Wh"
        },
        {
          "label": "Preconditioning",
          "value": "Fully charged 48 h before the test; ≥ 4.1 V verified; enclosures removed"
        },
        {
          "label": "Extinguisher",
          "value": "6 L, FW-18"
        }
      ],
      "procedure": [
        "Overcharge group #3 to induce thermal runaway by electrical abuse.",
        "When the first battery enters thermal runaway, discharge the extinguisher.",
        "Observe for 20 minutes, then measure the battery voltages."
      ],
      "criteria": [
        "All flames are extinguished and all batteries remain inside the test apparatus.",
        "No re-ignition during the 20-minute observation; at least one group of 4 cells in series has not caught fire and holds a cell voltage of ≥ 3.7 V.",
        "Agent consumption ≤ 9 L for a 600 Wh battery module."
      ],
      "result": {
        "summary": "One 6 L FW-18 extinguisher put out the 710.4 Wh pack fire; three groups kept their voltage.",
        "rows": [
          {
            "label": "Flame extinguished",
            "value": "Yes"
          },
          {
            "label": "Thermal runaway again within 20 min",
            "value": "No"
          },
          {
            "label": "Groups with qualified voltage",
            "value": "3 of 6"
          },
          {
            "label": "Group voltages #1–#6 (V)",
            "value": "16.36 / 0 / 0 / 0 / 16.65 / 16.83"
          },
          {
            "label": "Meets acceptance criteria",
            "value": "Yes"
          }
        ]
      },
      "videos": [
        "lco-6l-extinguishing",
        "lco-6l-voltage-check"
      ],
      "images": [
        "lco-test-module",
        "lco-test-stand"
      ]
    },
    {
      "id": "ncm-handheld",
      "title": "Portable extinguisher test: NCM pack",
      "slides": [
        17,
        18
      ],
      "kind": "In-house test",
      "method_reference": "NTA 8133+A1",
      "method_reference_slide": 17,
      "setup": [
        {
          "label": "Cells",
          "value": "LG E61 NCM pouch cells, 11.5 × 98 × 350 mm"
        },
        {
          "label": "Test pack",
          "value": "5 cells, 1128.5 Wh"
        },
        {
          "label": "Preconditioning",
          "value": "Fully charged 48 h before the test; ≥ 4.05 V verified"
        },
        {
          "label": "Extinguisher",
          "value": "6 L, FW-18, pre-heated to 40 °C"
        }
      ],
      "procedure": [
        "Pre-heat the whole extinguisher to 40 °C.",
        "Place a 300 W heating device between cells #1 and #2 and raise the temperature at 5–10 °C/min.",
        "When the first cell goes into thermal runaway, discharge the extinguisher immediately.",
        "Observe for 1 hour, then measure the cell voltages."
      ],
      "criteria": [
        "The flame is completely extinguished and there is no re-ignition within 1 hour.",
        "After 1 hour, at least one unburned cell remains, with a voltage above 3.7 V.",
        "Agent consumption ≤ 9 L for a 1000 Wh battery module."
      ],
      "result": {
        "summary": "One 6 L FW-18 extinguisher put out the 1128.5 Wh pack fire; four of five cells kept their voltage.",
        "rows": [
          {
            "label": "Flame extinguished",
            "value": "Yes"
          },
          {
            "label": "Thermal runaway again",
            "value": "No"
          },
          {
            "label": "Cells with qualified voltage",
            "value": "4 of 5"
          },
          {
            "label": "Cell voltages #1–#5 (V)",
            "value": "thermal runaway / 4.06 / 4.09 / 4.07 / 4.10"
          },
          {
            "label": "Meets acceptance criteria",
            "value": "Yes"
          }
        ]
      },
      "videos": [
        "ncm-6l-extinguishing",
        "ncm-6l-voltage-check"
      ],
      "images": [
        "ncm-test-setup"
      ]
    },
    {
      "id": "class-a",
      "title": "Class A fire test: wood cribs",
      "slides": [
        19,
        20
      ],
      "kind": "In-house test",
      "method_reference": "GB 4351 portable fire extinguishers",
      "method_reference_slide": 19,
      "setup": [
        {
          "label": "Wood crib",
          "value": "On a support of two angle irons, top (400 ± 10) mm above ground; sticks of (39 ± 1) mm square cross-section"
        },
        {
          "label": "Extinguishers",
          "value": "950 mL, 3 L and 30 L, FW-18"
        }
      ],
      "procedure": [
        "Place the ignition pan under the crib and add water to a depth of 30 mm.",
        "Weigh the crib; the target mass is (55 ± 2)% of the initial mass.",
        "Pour fuel into the pan and ignite it.",
        "When the crib has burned down to the target mass, discharge the extinguisher continuously at full opening: first from 1.8 m in front of the crib, then closer, onto the top, bottom, front and sides, not the back.",
        "Observe for 10 minutes."
      ],
      "criteria": [
        "The fire is completely extinguished and there is no visible flame within 10 minutes after the extinguisher is fully discharged.",
        "If the crib collapses during the test, the test is invalid and is repeated."
      ],
      "cribs": {
        "columns": [
          "Class",
          "Sticks",
          "Stick length (mm)",
          "Arrangement",
          "Ignition pan (mm)",
          "Ignition fuel"
        ],
        "rows": [
          [
            "0.5A",
            "45",
            "400",
            "9 layers × 5 sticks",
            "300 × 300 × 100",
            "0.63"
          ],
          [
            "2A",
            "112",
            "635",
            "16 layers × 7 sticks",
            "535 × 535 × 100",
            "2.0"
          ],
          [
            "6A",
            "230",
            "925",
            "23 layers × 10 sticks",
            "825 × 825 × 100",
            "4.8"
          ]
        ]
      },
      "result": {
        "summary": "All three sizes put out their crib with no re-ignition within 10 minutes.",
        "columns": [
          "Extinguisher",
          "Flame extinguished",
          "Re-ignition within 10 min",
          "Rating",
          "Meets criteria"
        ],
        "table": [
          [
            "950 mL FW-18",
            "Yes",
            "No",
            "0.5A",
            "Yes"
          ],
          [
            "3 L FW-18",
            "Yes",
            "No",
            "2A",
            "Yes"
          ],
          [
            "30 L FW-18",
            "Yes",
            "No",
            "6A",
            "Yes"
          ]
        ]
      },
      "videos": [
        "class-a-950ml-0-5a",
        "class-a-3l-2a",
        "class-a-30l-6a"
      ],
      "images": []
    }
  ],
  "agent_comparison": {
    "title": "Conventional extinguishing agents on lithium-ion battery fires",
    "slide": 5,
    "columns": [
      "Agent type",
      "Common agents",
      "Mechanism",
      "Effect on Li-ion battery fires"
    ],
    "rows": [
      [
        "Gaseous",
        "Halon 1301, Halon 1211",
        "Chemical inhibition",
        "Fast, but the fire easily rekindles"
      ],
      [
        "Gaseous",
        "CO₂, IG-541, IG-100",
        "Smothering",
        "Limited effect, poor cooling, prone to re-ignition"
      ],
      [
        "Gaseous",
        "HFC-227ea, 2-BTP",
        "Cooling, smothering, chemical inhibition",
        "Poor in large spaces, limited cooling, prone to re-ignition"
      ],
      [
        "Dry powder",
        "ABC dry powder",
        "Isolation, cooling, smothering, chemical inhibition",
        "Almost no effect, prone to re-ignition"
      ],
      [
        "Aerosol",
        "K-type, S-type",
        "Smothering, chemical inhibition",
        "Fast, but prone to re-ignition"
      ],
      [
        "Liquid",
        "Water, AF-31, A-B-D",
        "Cooling",
        "Unremarkable cooling, high water consumption, conductive, risk of re-ignition"
      ],
      [
        "Liquid",
        "Foam",
        "Cooling, separation",
        "Unremarkable cooling, conductive, risk of re-ignition"
      ],
      [
        "Liquid",
        "Ordinary water-based agent",
        "Cooling",
        "Good cooling; conductive, no explosion suppression"
      ],
      [
        "Liquid",
        "FW-18",
        "Cooling and chemical inhibition",
        "Rapid fire suppression, efficient cooling, explosion suppression, termination of thermal runaway, insulating and non-conductive"
      ]
    ]
  },
  "qualifications": {
    "slides": [
      22,
      23,
      24,
      25
    ],
    "items": [
      {
        "label": "Type test report",
        "value": "1"
      },
      {
        "label": "Commissioned test reports",
        "value": "3"
      },
      {
        "label": "1500 V voltage breakdown test report",
        "value": "1"
      },
      {
        "label": "Technical appraisal certificate for a lithium-ion battery dedicated extinguishing agent (China)",
        "value": "Obtained"
      },
      {
        "label": "Patent applications",
        "value": "32"
      },
      {
        "label": "Authorized invention patents",
        "value": "4"
      },
      {
        "label": "Authorized utility model patents",
        "value": "3"
      },
      {
        "label": "Registered software copyrights",
        "value": "6"
      },
      {
        "label": "Academic papers",
        "value": "26"
      }
    ]
  }
}